Programming
g the Receiver and Transmitters
1. With at least one 2-line Alpha keypad (5137AD or 6139) connectedto the
Partition 1 terminals, power up the system temporarily. If you had
previously connectedthe AC transformer to the control paneI, you need
only plug in the transformer (to 120VAC outlet) to powerup the system.
2. Enter the programming modeby keying the following
Installer code(4112)+ 8+0+0.
3. *24. RF HOUSE ID CODE
m
The House ID identifies wirelesskeypads.
If a 5827 or 5827BD Wireless keypad is to be used, a House ID code
MUST be entered (01-31), and the keypad should be setto the sameID.
If no wirelesskeypad is to be used, enter “00”.
Partition 2 House ID is automaticallysetfor one number higher than the
ID number enteredfor Partition 1. Therefore, if a wirelesskeypad is also
used in partition 2, the House ID for partition 1 must not be higher than
30.
4. Press *56.
(ZoneProgramming Mode)
Use this mode to program zone numbers, zone types, partition numbers,
alarm report codes, and to learn RF devices for all wireless expansion
zonesthat are goingto be used in the system.
w
IMPORTANCE
If
wiredexpansionzonesarenot presentlybeing
usedin the system,but if thereis anypossibilim
thattheymaybeaddedat somefkturedate,you
shouldassignzonenumbersin the rangeof 16-
63for wirelesstransmitters.
Thereasonforthisis asfollows:wiredexpansion
zone numbers are restrictedto 10-17; if you
assign zone numbers between 10 and 17 for
wireless,and subsequentlyadd wiredexpansion
zones,
all serial numbers for wireless
transmittersin the 10-17 zone number range
will be lost. and any transmittersassignedto
thosenumbers will becomeinoperativein the
system.Theseparticulartransmitterswill then
have to be assignedMerent zonenumbers(in
therangeof 16-63)end their serialnumbersre-
learned.
~,
Enter the zone number that you wish to
program. As an example, zone 20 is shown
entered.
You can assignzone
numbers to Ixansmittersas
follows:
●
●
●
Use zone numbers in the range of 10-63 if a
4219 or 4229 is NOT being used in the
system.
Use zone numbers in the range of 18-63 if a
4219 or 4229 IS ALSO being used in the
system,
even if some of the expansion unit’s
wired loops are not being used.
The actual number of zones that can be
assignedto wirelessis
24, but will be lessif a
wired expansion module is being used (see
“General Information” at the beginning of
this section).
Note:
M?ter
If using a button for arming, the zone
number assigned to the button is the
“user number” reported to the central
skm-rnstation, i.e., arm button = zone x,
disarm button = zoney.
entry of zone number, press [*I to
continue.
A summary display will appear, showing the
statusof that zone’sprogram.
If it is programmed satisfactorily, press [#l to
back up one step and enter another zone
number, if desired.
If the zone is not programmed, or you want to
change it, press [*]. A prompt for Zone Type
will appear.