General information
You must assign a zone type to each zone,which will then define the way in
which the systemwill respond to faults in that zone. Zone types are defined
below.
Type 00
Zone Not Used
~ 01
En&y/Exit Burglary #1
we 02
Entry/Exit Burglary W
Type03
Perimeter Burglary
Type04
Interior, Follower
Type05
Trouble by Day/
Alarm by Night
Progmuna zone with this zone@pe if the zone is not used.
This zone type providesexit and entry delayswhenever the zone is faulted if
the controlis armed in the Away or Stay modes.When the panel is armed in
the Instant or Maximum modes,no entry delay is provided. Entry delay #1 is
programmable,but Exit delay is automaticallysetas follows:
Exit Delay = Entry Delay (that has beenprogrammed) +40 seconds.
Exit delay begins whenever the control is armed, regardless of the arming
mode selected.This zone type is usually assigned to sensors or contactson
doorsthrough whichprimary en~ and exit will take place.
This zonetype providesa secondaryentry delay whenever the zone is faulted
if the panel is armed in the Away and Stay modes. When the panel is armed
in the Instant or Mazimum modes,no entry delay is provided. Enlz-y and Exit
delays#2 are automaticallysetas follows:
Entry delay #2= programmed Entry delay #1 + 30 seconds.
Ezit delay #2 = programmed Entry delay #1 + 40 seconds.
Exit delay #2 beginswhenever the controlis anneal,regardless of the arming
modeselected.
This zone type is usually assigned to sensorsor contactson doors through
which secondaryentry and ezit will take place, and where more time might
be neededto getta end from the keypad (typically used for a garage, loading
dock,or basementdoor).
This zonetype givesan instant alarm if the zone is faulted when the panelis
armed in the Away, Stay, Instant or Maximum modes. This zone type is
usually assignedto all sensorsor contactson exterior doorsand windows.
This zone type gives a delayed alarm (using the programmed Entry/Exit
time) if the Entry/Exit zone is faulted first. Otherwise this zone lype givesan
instant alarm. This zone type is activewhen the panel is armed in the Away
and Maximum modes.This zone me is bypassed automatically when
the panel is armed in the Stay or Instant modes. This zone type is
usually assignedto a zonecoveringan area such as a foyer,lobby, or hallway
through which onemust pazs upon entry (After faukiug the entry/exit zoneto
reachthe keypad to disarm the system.)
Sincethis zone type is designed to provide an instant slain if the enh-y/ezit
zoneis not violatedfirst, it will protectan area in the event an intruder hides
on the premises prior to the system being armed, or gains accessto the
premisesthrough an unprotectedarea.
This zone type will give an instant alarm if faulted when armed in the Away,
Stay, Instant or Msximum (night) modes. During the disarmed state (day),
the system will provide a latched tiouble sounding from the keypad (and a
central station report, if desired). This zonetype is usually assignedto a zone
which contains a foil-protected door or window (such as in a store), or to a
zone coveringa “sensitive”area such as a stockroom, drug supply room, etc.
This zone type can also be used on a sensor or contact in an area where
immediatenotificationof an entry is desired.